Burners IL-G (gas) / IL-GL (gas-light oil)

SibStrong gas burners are manufactured in accordance with international and Russian standards applicable to the production and operation of gas equipment.

All components of the burners of our own production undergo multi-stage quality control.

The applied gas equipment and automation of leading Russian and foreign manufacturers ensures high industrial and environmental safety and stability of the SibStrong burners.

TECHNICAL AND FUNCTIONAL CHARACTERISTICS

  • SibStrong gas burners are manufactured in accordance with international and Russian standards applicable to the production and operation of gas equipment.
  • All burner components of our own production undergo multi-stage quality control.
  • Operate in two-stage and modulation mode.
  • Power control in modulating mode is carried out using an electronic regulator installed on the burner control panel.
  • The main fuel is natural gas.
  • The formation of a gas-air mixture without premixing occurs in the burner tube.
  • Used to work with all types of combustion chambers.
  • The possibility of the most complete combustion of gas in modulating burners is achieved by electronic control of the ratio of air and gas.
  • Automatic blocking of air access to the furnace when the burner stops working.
  • Available with threaded or flanged gas train connection
  • Maximum gas pressure in front of the burner up to 300 mbar. or up to 500 mbar.
  • The composition of the gas train: control, operating and safety valve, valve tightness control unit, minimum and maximum gas pressure switches, pressure regulator and filter.
  • Air flow control by electric servomotor.
  • The burner is equipped with a mounting flange and sealing gasket, as well as a gas train

IL-G2 - two-stage, IL-GM - modulating, IL-GL - combined (gas-light oil)

IL-G2
IL-GM
CapacityOil consumption, gasPower consumptionMotor powerWeight without gas ramp, no more
IL-5G2/M 465-1200 kW/h 48-125 m³/hour 1,7 kW 1,5 kW 62 kg
IL-7G2/M 600-1800 kW/h 62-187 m³/hour 3,2 kW 3 kW 108 kg
IL-8G2/M 700-2900 kW/h 73-302 m³/hour 4,2 kW 4 kW 113 kg
IL-8G2A/M 700-3200 kW/h 73-334 m³/hour 4,2 kW 4 kW 113 kg
IL-9G2/M 1000-4000 kW/h 104-417 m³/hour 5,7 kW 5,5 kW 208 kg
IL-10G2/M 1200-6000 kW/h 125-520 m³/hour 11,1 kW 11 kW 208 kg

 

IL-GL2
IL-GLM
CapacityOil consumption, gasOil consumption, light oilPower consumptionMotor powerWeight without gas ramp, no more
IL-5GL2/M 465-1200 kW/h 48-125 m³/hour 39-101 kg/h 2,9 kW 1,5 kW 62 kg
IL-7GL2/M 600-1800 kW/h 62-187 m³/hour 50-152 kg/h 4,4 kW 3 kW 108 kg
IL-8GL2/M 700-2900 kW/h 73-302 m³/hour 59-245 kg/h 5,4 kW 4 kW 113 kg
IL-8GL2A/M 700-3200 kW/h 73-334 m³/hour 59-270 kg/h 5,4 kW 4 kW 113 kg
IL-9GL2/M 1000-4000 kW/h 104-417 m³/hour 85-337 kg/h 7,3 kW 5,5 kW 208 kg
IL-1OGL2/M 1200-6000 kW/h 125-520 m³/hour 101-506 kg/h 12,6 kW 11 kW 208 kg

 

* Type of regulation - two-stage modulating

Dimensions (mm)

Burner typeАВСdКDFGНNLМ
IL-5G 960 700 370 185 210 460 550 184 234 120 165 М12
IL-7G 1120 805 400 200 220 300 630 274 262 135 193 М12
IL-8G 1120 880 430 240 220 300 630 274 262 135 193 М12
IL-9G 1790 880 655 280 200 355 655 344 275 150 242 М16
IL-10G 1790 880 655 280 200 355 655 344 275 150 242 М16


Чертежи и габаритные размеры газовых горелок IL-G/GL

Power diagrams

Power diagrams газовых горелок IL-G

COMPLETE BURNERS STANDARD

Burner body, body cover, burner counter-swivel flange, flange seal, burner motor, fan wheel, gas solenoid valve system, light oil burner fuel assembly and nozzles (for IL-GL), control panel with burner control , burner tube with turbulator, air damper with air regulator servo drive (for single-stage burners without servo drive), gas throttle servo drives, oil fuel regulator servo drive (for IL-GM/GLM), ignition transformer, ignition cables, ignition electrodes, ionization electrode, sensor flame, external pumping station (NSh pump), fuel hoses, pressure reducing valve, pressure gauge, gas filter, gas pressure regulator, minimum and maximum gas pressure sensor, safety solenoid valve (for IL-5), shut-off valves of the first and second stages (for IL-7 - IL-10), valve tightness control devices (for IL-7 - IL-10).

ADDITIONAL PACKAGE IS POSSIBLE

  • single adapter flange
  • double reducer flange
  • heat-insulated adapter flange
  • non-standard burner tube length
  • ball valves with flanged or threaded ends

PERFORMANCE REQUIREMENTS

  • Fuel used for combustion in burners: GOST 5542-2014 "Combustible natural gases for industrial and domestic purposes", GOST 305-2013 "Diesel fuel"
  • Power supply voltage, nominal: 220-380 V, 50 Hz
  • The amount of emissions of nitrogen oxides and carbon monoxide does not exceed the standards established by the technical regulations of the Russian Federation and is: NOx≤85 mg/kW h; CO≤50 mg/kWh
  • Noise level 60-70 dB

CONSTRUCTION CHARACTERISTICS

  • Aluminum alloy burner body
  • A highly efficient fan that ensures reliable operation of the burner, also on boilers with increased pressure in the furnace.
  • Air intake with air flow adjustment device.
  • One three-phase electric motor drives the fan.
  • One electric servomotor with mechanical cam for air/fuel ratio control on stage burners and two electronically controlled servomotors on modulating burners.
  • Automatic control and burner control unit.
  • The presence of a flame is controlled by a photo sensor or an ionization electrode.
  • Air pressure switch.
  • Control panel includes: start/stop switches, burner operation and lockout indicators.
  • Terminal block for power supply and connection of thermostats for 1st and 2nd stage burner control or connection of a modulating power controller.
  • The degree of dust and moisture protection of the burner is IP40.